WHY CHOOSE THE Davey TorriumÂ2 Plug & Play Controller?
Constant Flow and Even Water Pressure
To prevent annoying fluctuations in water temperature during showers, TorriumÂ2 uses its intelligence to provide households with constant flow to give even water pressure. It does this with its innovative pressure and flow sensors to start the pump on a pressure drop and to stop it on low flow (~1 lpm). This avoids pump cycling when there is continuing household demand for water.
Quick Cut-in for Even Pressure
To give you strong pressure right from the start, TorriumÂ2 is designed to cut in quickly when it senses demand for water. It cuts in when the pressure has dropped to 80% of the previous top (shut-off) pressure. It uses its intelligence to automatically set this cut-in pressure each time the pump stops. In doing so, it allows the system to automatically accommodate for variations in pump performance or site conditions.
Adaptive Starting
TorriumÂ2 is clever enough to detect the difference between normal water demand and a small leak in the system, such as a dripping faucet or a leaking cistern. For very low flows, TorriumÂ2 automatically adapts to reduce the cut-in pressure, which can be as low as 50% of its last shut-off pressure. This significantly reduces pump cycling to improve consumer satisfaction with the system. If normal flow is required in the house (>0.5 lpm), TorriumÂ2 will sense this and revert to normal mode and initiate an immediate pump start.
Easy Status Check
To easily check the system status, TorriumÂ2 has three simple LED indicators.
Red LED - the system is in standby mode
Green LED - the pump is running
Pressure Indicator Window
To give a quick guide to the system pressure, TorriumÂ2 has a pressure indicator window on the side of the inbuilt pressure vessel. If the colour band (green-yellow-red) is mainly green it indicates maximum pressure, whereas mainly red indicates low pressure. This indicator can help to analyse the occurrence of unwanted system leaks. If the colour band indicator is moving slowly towards red this signifies a slow drop in pressure and may indicate a small leak.
Greater Hydraulic Performance
For better hydraulic performance to supply more pressure with less wasted energy, TorriumÂ2 has been designed with larger water pathways and no moving parts in the pathways. This performance versus loss equation is especially evident at higher flow rates.
Greater Reliability
To diminish the likelihood of blockages, TorriumÂ2 is designed with no moving control parts within the water pathways giving greater reliability and performance with varying water quality.
Dry Run Protection and Auto Restart
To protect the pump from damage due to dry running, TorriumÂ2 stops the pump when it detects a loss of prime (no water supply) situation. To reduce system downtime, the TorriumÂ2 waits 5 minutes then goes into auto retry mode, whereby it will restart the pump to see if prime can be re-established automatically. An auto restart occurs at 5 minutes, 30 minutes, 1 hour, 2, 4, 8, 16 and 32 hours. TorriumÂ2 will also restart if it detects flow through the system (e.g. from mains water pressure returning with pressure boosting applications).
Pump Protection _ High Water Temperature Cut-out
For added security and longer life, a water over-temperature cut-out provides a second level of protection against closed head operation and repetitive cycling. For water temperatures above 70çC TorriumÂ2 will shut the pump down and the amber LED will be lit. When the water temperature drops to below 60çC, the TorriumÂ2 will allow the pump to restart.
Pump Protection _ Excessive Electrical Current
To protect the pump motor, TorriumÂ2 will shut the pump down and indicate a fault if it detects excessive electrical current being drawn. This occurs if the pump motor is subjected to locked rotor or if someone tries to manually override the TorriumÂ2 by continually holding in the prime button.
Corrosion and Scale Resistance
To allow TorriumÂ2 to be used with water of varying quality, its flow sensors are mounted on a high grade stainless steel plate with special anti-scaling electronic action, which only turns the flow sensors on during pump operation.
Extra Draw off Capacity
To accommodate small leaks and to reduce cycling, TorriumÂ2 has an in-built spring loaded accumulator for extra draw off capacity. A spring loaded accumulator means low maintenance as there is no need for a pressure vessel with its regular air charging and checking. However, for increased draw off, an optional pressure tank, up to 18 litres, can be mounted on the vertical outlet.
Power Surge Protection for TorriumÂ2
To protect the TorriumÂ2 controller from electrical surges and spikes, thus extending its life, it has an in-built metal oxide varistor (MOV). The status of the MOV can be checked in the viewing window on the back of the TorriumÂ2. The MOV is a sacrificial component and should it be consumed due to repeated power surges or spikes, it will almost always blacken the viewing port. This will indicate a non-warrantable TorriumÂ2 failure.
Ease of Installation
For ease of installation, the plumbing can be connected to either the vertical or the right angle discharge outlet, which can rotate a full 360ç. A spanner, sized to fit the coupling, is included in the box. Also, for increased draw off, an optional pressure tank, up to 18 litres, can be mounted on the vertical outlet.
Electrical Connection For easy installation
TorriumÂ2 (TT45/S & TT70/S) comes with an incoming 2 metre long power lead, fitted with an Australian male three pin plug. To easily connect to a manual pump, the TorriumÂ2 also includes an Australian female three pin power socket for indoor installation. A lead safety box can be fitted over the controller/pump connection to increase the IP rating of the TT45/S or TT70/S to that of the lead safety box or IP56, whichever is lower